Electrodes For Fusion Splicer
Electrodes For Fusion Splicer
Fujikura ELCT2-20A | FSM-50S,FSM-50R,FSM-60S,FSM-60R,FSM-61S,FSM-62S,FSM-70S,FSM-70S+,FSM-80S,FSM-17S,FSM-17S-FH,FSM-18S,FSM-18R,FSM-19S,FSM-19R |
Sumitomo ER-10 | TYPE-25eS,TYPE-25eU,TYPE-25eM,TYPE-39/FH,TYPE-66,TYPE-81C,TYPE-71,TYPE-46,T400S,T400S+,T-600C,T81M12,TZ1C,T-55,TYPE-Q101 |
Fitel S960 | S174,S175,S175V2000,S176CF,S176CR,S176LP,S177,S177A,S177B,S182A,S182PM,S198A,DVP-720A,DVP-720B,DVP730,DVP730H,DVP750 |
Fujikura 40S | FSM-40S,FSM-40PM,FSM-40F,FSM-45FS,FSM-45PM,FSM-45F,FSM-30S,FSM-20PMII,FSM-20PM,FSM-20CSII,FSM-20CS,FSM-20C |
Ilsintech EI-21 | S3 S5 KF4 K3 K7 K11 |
Comway CE-03 | C6,C8,C9,C10 |
Ilsintech EI-19 | Swift-F1 Swift-F3 KF2A |
INNO E27 | IFS-15 IFS-10 View3 View5 View7 IFS-15 V7 V3 V5 |
CETC41 Electrodes | CETC AV6471 AV6471A AV6471AG AV6496A |
DVP | DVP-600 DVP-720A DVP-720B 730 730A 730B 750 |
Fitel S969 Electrodes | S178A/S153A/S123A/S123M4-A/S123M4-B/S123M12 |
Fujikura ELCT2-12 | Fujikura FSM-12S/FSM11R/11S /21S /12R FSM-22S |
Change electrode method:
First, must confirm the welding machine in a shutdown state, take the electrode chamber protective cover, screw loosen the fixed electrode extraction electrode; then release the electrode silk top, remove the lower electrode.
Secondly, the installation of new electrode, the operation steps and the method of removing the electrode is the opposite, in turn, can be operated. The two electrode tip clearance requirements for : 2.6 + / - 0.2 mm.
Finally, in the assembly process, not can touch the tip of the electrode and to prevent damage to the electrode, and avoid electrode fall into the machine internal damage caused by. After replacing the electrode, the arc position should be calibrated
Electrode cleaning and arc calibration:
1. In the electrode after the installation is complete, open welding machine power switch.
2. Welding machine into the initial screen, press the menu button to enter the menu.
3. Through the movement of the cursor is located the machine maintenance and cleaning electrode entry. After confirmation, machine will automatically discharge cleaning and electrode aging.
4. Installation must good left / right fiber, through the movement of the cursor to find the arc position, through the operation of the fiber end and two electrode tips to keep the three-point line position, the machine will discharge test, according to the actual situation can be adjusted.
5 Finally, press the menu key, turn out.